RFD Series In-Tank / Inline Duplex Filters 360 PSI • Up to 400 GPM Features
|
Technical Details
Mounting Method | 4 Mounting holes in the filter housing | ||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
Flow Direction | Inlet: Side Outlet: Bottom | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
Element Collapse Pressure Rating BN/HC, W/HC, V 250 psid (17 bar) |
ECO/N, BN/AM, P/HC, AM 145 psid (10 bar) |
||||||||||||||||||||||||
Fluid Temperature Range | -22° to 250°F (-30° to 121°C) | ||||||||||||||||||||||||
Fluid Compatability Compatible with all petroleum oils and synthetic fluids rated for use with Fluoroelastomer or Ethylene Propylene seals. Contact Womack for information on special housing and element constructions available for use with water glycols, oil/water emulsions, and HWBF. |
|||||||||||||||||||||||||
Indicator Trip Pressure P = 29 psi (2 bar) - 10% (standard) |
P = 72 psi (5 bar) - 10% (optional) |
||||||||||||||||||||||||
Bypass Valve Cracking Pressure ΔP = 15 psid (1 bar) +10% ΔP = 43 psid (3 bar) +10% (standard) |
ΔP = 87 psid (6 bar) +10% (optional) |
Available in: Alabama, Arizona, Arkansas, N.W. Florida, S. Idaho, Kansas, Louisiana, Mississippi, W. Missouri, Montana, Nevada, New Mexico, W. North Dakota, Oklahoma, W. South Dakota, Texas, Utah and Wyoming