FCU 1000 Series

Hydac_FCU 1000

Description

The Fluid Control Unit FCU 1000 series combines the advantages of the portable contamination measurement units FCU 2000 series with the measurement technology of the Contamination Sensor CS 1000. The FCU 1000 is a portable service unit and is designed for temporary measurement of solid particle contamination in hydraulic systems. The integrated pump and the hoses which are contained in the scope of delivery of the FCU 1000 series.

  • Control circuits
  • Pressure circuits
  • Fluid sampling from pressureless reservoirs

 

Applications

  • Hydraulic systems
  • Service for mobile hydraulics
  • Maintenance

Advantages

  • Cleanliness classes ISO and SAE or NAS
  • Integration of AquaSensor AS 1000 for measurement of moisture and temperature
  • Applicable for hydraulic fluids up to 350 mm²/s

Technical Details

GENERAL DATA

Operation intermitting
(S4, according DIN EN 60034/VDE 0530)
Self-diagnostics continuously with error indication viastatus LED and display
Display LED, 6 / 4 / 4 digits, in 17 segment format
Measured value ISO code / SAE Class / NAS Class /
Saturation level / Temperature
Measuring range Display from ISO code 9/8/7 (MIN) to ISO code 25/24/23 (MAX)
Calibrated within the range ISO 13/11/10 ... ISO 23/21/18
Saturation level 0 ... 100%
Temperature -25 ... 100°C / -13 ... 212°F
Accuracy +/- 1/2 ISO class in the calibrated range /
≤ 2 % Full scale max.
Sealing material FPM
Ambient temperature range 0 ... +45°C / 32 ... 113°F
Storage temperature range -40 ... +80°C / -40 ... 176°F
IP class IP50 in operation
IP67 when case is closed
Weight ≈ 13 kg

HYDRAULIC DATA

Operating pressure


with adaptor for pressure lines
IN: - 0.5 ... 45 bar / -7.25 ... 650 psi
OUT: 0 ... 0.5 bar / 0 ... 7.5 psi

IN: 15 ... 345 bar / 217 ... 5000 psi
OUT: 0 ... 0.5 bar / 0 ... 7.5 psi
Maximum pressure 345 bar / 5000 psi
Measurement flow rate 30 ... 300 ml/min (depending on viscosity)
Maximal suction height 1 m
Permissible viscosity range 10 ... 350 mm²/s
46 ... 1622 Sus
(for hydraulic oils up to ISO VG 68)
Fluid temperature range 0 ... +70°C / 32 ... 158°F

ELECTRICAL DATA

Power supply voltage 24 VDC ±20%, residual ripple < 10%
Max. power / current consumption 100 Watt / 4000 mA
Interface Plug connection, 5-pole, male, M12x1 and
Bluetooth 1.2, Class 3
(HYDAC Sensor Interface - HSI, only)