Function
- The STD1 processes incremental input signals from Stauff volume counters and other sensors
- The input signals are filtered in the unit, then interpreted, and then converted into values of flow rate
- The user may choose to have either flow rate or volume displayed
- One analog output is available for further external processing
Product Characteristics
- Programmable microprocessor
- Flow rate and volume measurement
- Selectable time basis (sec, min, hrs)
- Selectable units for display
- Selected analog outputs include ±10V, 0-10V, ±20mA, 0-20mA, and 4-20mA
- Power supply voltage options include 230 VAC, 115 VAC, 24 VDC, and 12 VDC
- Enclosure dimensions to DIN standard (96 x 48 x 120)
|