ETS 300 Series

Hydac_Temp Switch_ETS300

The ETS 300 is a compact, electronic temperature switch with digital display. It is used with the TFP 100 temperature sensor, which was especially developed for tank mounting, or with its own integral sensor.

The ETS 300 has a 2 temperature ranges allowing for use in a wide range of industrial applications: -13° to 212°F (-25° to 100° C) and -22° to 302°F (-30° to 150°C).

The ETS 300 is offered with one or two switching outputs with an optional 4 to 20 mA analog output signal for remote temperature monitoring.

The switching points and hysteresis are easily adjustable via the membrane keypad. Other parameters are accessible and displayed on the digital readout, then adjustable via the keypad.

 

Technical Details

INPUT DATA FOR INTEGRAL SENSOR

Measuring range -13° to 212°F (-25° to 100°C)
Pressure resistance 13,000 psi (600 bar)
Hydraulic connection G 1/2 A male
Torque rating approx. 33 lb-ft (45 Nm)
Parts in contact with media Stainless steel, Seal: FPM

INPUT DATA FOR SEPARATE SENSOR

Display range -22 to 302°F (-30° to 150°C)
Sensor connection M 12x1, 4 pole

OUTPUT DATA

Accuracy (display, analog output) ≤ ± 2.0°F (≤ ± 1.0°C)
Temperature drift (zero point and range) ≤ ± 0.0085% / °F
Reaction time (T09) approx. 20 s
Analog output 4 to 20 mA, ohmic resistance ≤ 400

SWITCHING OUTPUTS

Type PNP transistor output
Switching current max. 1.2 A

AMBIENT CONDITIONS

Temperature range of medium -13° to 212°F (integral sensor)
Ambient temperature range -13° to 176°F (-25° to 80°C)
Storage temperature range -40° to 176°F (-40° to 80°C)
Compensated temperature range -14° to 158°F (-26° to 70°C)
CE mark EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4
Vibration resistance approx. 10 g / 0 to 500 Hz
Shock resistance approx. 50 g / 1ms

OTHER DATA

Supply voltage 20 to 32 VDC
Current consumption approx. 100 mA (without switching output)
Safety type IP 65
Material of housing tube: stainless steel
keypad housing: PA6.6 Gf30
Display 3 digit, 7 segment LED, red,
height of digits 9.2 mm
Weight approx. 300 g

 

TEMPERATURE SENSOR TFP 100

Temperature range of medium -40° to 257°F (-40° to 125°C)
Electrical connection 4 pole plug M18x1

SAFETY SLEEVE FOR TANK-MOUNTING THE TFP 100

Parts in contact with medium All materials compatible with nickel

 

 

ETS 1700 Series

Hydac_Temp Switch_ETS1700

The electronic temperature switch ETS 1700 is used together with the temperature sensor TFP 100, which was specifically developed for tank mounting.

The 4 digit display can indicate either the actual temperature, one of the switching points, or the maximum temperature. The maximum temperature indicates the highest temperature which has occurred since the unit was switched on or last reset.

The 4 switching outputs can be used to control heating and cooling processes in hydraulic systems. All switching and switch-back points, which are independent of each other, can be adjusted very simply via a membrane keypad. For incorporation into monitoring systems (e.g. with PLC), an analog output (4 to 20 mA or 0 to 10 V) is also available.

 

Technical Details

INPUT DATA

Measuring range 32° to 212°F (0° to 100°C)

OUTPUT DATA

Output signal 4 to 20 mA, ohmic resistance ≤ 400
0 to 10 V, ohmic resistance ≥ 2k
Accuracy (display, analog output) ≤ ± 1.0% of the measuring range
Repeatability ≤ ± 0.25% of the measuring range
Temperature drift in the zero point ≤ ± 0.054%/°F (≤ ± 0.03%/°C)
Ambient temperature range ≤ ± 0.054%/°F (≤ ± 0.03%/°C)
Switching output type 4 relays with change-over contacts in 2 groups
(common supply of each group connected)
Switching voltage 0.1 to 250 VAC / VDC
Switching current 0.009 to 2 A
Switching capacity 400 VA, 50 W (for inductive load use varistors)
Life expectancy of contacts ≥ 20 million (minimum load)
≥ 1 million (maximum load)
Reaction time (without switching delay) approx. 20 ms
Switching point setting range 1.5 to 100% FS
Setting range of hysteresis / switch-back points 1 to 99% FS

AMBIENT CONDITIONS

Ambient temperature range -13 to 140 °F (-25 to 60°C)
Storage temperature range -40 to 176 °F (-40 to 80°C)
CE mark EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4
Vibration resistance approx. 5 g
Shock resistance approx. 10 g
Sensor connection 5 pole DIN connector

OTHER DATA

Supply voltage 22 to 32 VDC (residual ripple ≤ 10%)
Electrical connection 14 pole terminal strip
(cross-section of connection max. 1.5 mm²)
Current consumption approx. 200 mA
Display 4-digit, 7-segment LED, red, digits 13mm high
Safety type IP 65
Weight approx. 800 g

 

 

ETS 3000 Series

Hydac_Temp Switch_ETS3000

The electronic temperature switches ETS 3000 are available either as stand alone units with separate temperature probe or as pressure resistant types with integrated probe. Pressure resistant types have the sensor integrated and measuring ranges from -25° to 100°C. They stand pressures up to 600 bar which enable them to be mounted directly into pipes or manifolds. Types with separate temperature probes have measuring ranges from -30° to 150°C. As probes to be connected the HYDAC TFP 100 or other types of standard PT100 probes are applicable.

For evaluation and control the ETS 3000 feature 1 or 2 switching transistor outputs and, optionally, an analogue output. Maximum switching capacities are 1.2 A which enable connection of PLC input cards, as well as, direct connection of standard solenoid controlled valves. The digital displays are rotating over two axis (vertically and horizontally). Because of this, the ETS 3000 can be mounted in any position with their displays aligned into required positions. The 4 digit digital displays in standard operation show actual temperatures. Furthermore, maximum values or switch points can be displayed permanently. Selected by the user, either one of the measuring units °C or °F is displayed.

 

Technical Details

INPUT PARAMETERS

INTEGRAL SENSOR PROBE

EXTERNAL SENSOR PROBE

Measurement range -13° to 212°F (-25 to 100°C) -22 to 302°F (-30 to 150°C)
Pressure resistance 600 bar (18 mm)
50 bar (100, 250, 350 mm)
-
Hydraulic connection G1/2 A DIN 3852 -
Tightening torque 45 Nm -
Components in contact with fluid Stainless steel, seal: FPM -
Sensor connector - Cable connection M12x1, 4-pole

Output Parameters

Accuracy (display, analogue output) ≤ ± 2.0°F (≤ ± 1.0°C) ± 1.0% FS (+ PT100 error)
Temperature drift (ambient) ≤ ±0.15 % /10 K (zero point and range)
Reaction time (t90) approx. 20 sec -
Analogue output 0 to 10 V; ohmic resistance: min. 1 K
4 to 20 mA; ohmic resistance: ≤ 500

Switching Outputs

Type PNP transistor output
Switching current max. 1.2 A
Switching cycles > 100 million

Ambient Conditions

Temperature range of fluid (probe) -40° to 212°F (-40 to 100°C) -
Ambient temperature range -13° to 212°F (-25 to 85°C) -13° to 176°F (-25 to 80°C)
Storage temperature range -40° to 212°F (-40 to 85°C) -40° to 176°F (-40 to 80°C)
Rated temperature range -10 to 70°C
CE mark EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
Vibration resistance approx. 10 g / 0 to 500 Hz (IEC 60068-2-6)
Shock resistance approx. 50 g / 11 ms (IEC 60068-2-29)

Other Specifications

Supply voltage 18 to 35 VDC (version with analog output)
9 to 35 VDC (version without analog output)
Current consumption max. 35 mA (inactive switching output)
Protection type IP 67
Components in contact with fluid stainless steel
Display 4-digit, LED, 7-segment, red
Character height 7 mm
Weight approx. 135 g (18 mm)
approx. 150 g (100 mm)
approx. 185 g (250 mm)
approx. 210 g (350 mm)
87 g (unit only)