Pressure Sensor
PPC-PT Series

Stauff_Pressure Sensor_PPC_PT Product Description
The PPC-04/12-PT /2 pressure sensors can be used with all hydraulic testers of the PPC series, due to their 5-pin connection. As an additional feature, the new generation of PPC-04/12-PT sensors (identified with "/2" in the name) can now also measure and display temperature (only with the PPC-06/08/12 hydraulic testers). The STAUFF pressure sensors are a reliable and flexible solution for the PPC series because of their sturdy stainless-steel design, the quick response times (< 1 ms) and the high accuracy (± 0,25% FS* typ.) with automatic sensor recognition.

 

Specifications

  • Sturdy stainless-steel housing (1.4301)
  • FKM gasket (Viton ̈)
  • Weight:  0.44 lbs. (200 g)
  • Suitable for gases and liquids (in the case of aggressive media, only after consultation)
  • 5-pin connection
  • Pressure connection G 1/2 BSP (without adaptor), with STAUFF Test 20 (M 16 x 2) adaptor, for additional adaptors, see the STAUFF Test catalogue

Note: The temperature measurement data from the PPC-04/12-PT /2 sensors can only be displayed using the PPC-12 hydraulic testers. The units PPC-06/08- plus allow the evaluation and further processing of the measured values obtained.

Technical Data

Ambient Conditions

  • Media temperature:  max. 221°F (105°C)
  • Ambient temperature:  -13°F ... 176°F (-25°C ... 80°C)
  • Storage temperature:  -4°F ... 176°F (-20°C ... 80°C)
  • Compensated range:  32°F ... 285°F (0°C ... 85°C)
  • Load cycles (106):  100

Electrical Data and Output

  • Input voltage:  7 V ... 12 VDC
  • Current consumption:  ≤5 mA
  • Output signal:  0 V ... 3 VDC
  • Response time:  ≤1 ms
  • Long-term stability:  <0.2% full scale/a
  • Vibration loading:  IEC 68-2-6/10 ... 500 Hz
  • Shock loading:  IEC 68-2-29

 

Pressure Ranges and Accuracies

Ordering Code Sensor PPC-04/12-PT- 015 /2 060 /2 150 /2 400 /2 600 /2 601 /2
Pressure Measuring Range
PSI
(bar)
-15 ... 210
(-1 ... 15**)
0 ... 870
(0 ... 60)
0 ... 2,175
(0 ... 150)
0 ... 5,800
(0 ... 400)
0 ... 8,700
(0 ... 600)
0 ... 8,.700
(0 ... 600***)
Type of Measurement Relative pressure Absolute pressure Absolute pressure Absolute pressure Absolute pressure Absolute pressure
Maximum Pressure
PSI
(bar)
435
(30)
1,740
(120)
4,350
(300)
11,600
(800)
17,400
(1200)
17,400
(1200)
Burst Pressure
PSI
(bar)
2,.175
(150)
7,250
(500)
13,000
(900)
17,400
(1200)
26,100
(1800)
36,250
(2500)
Accuracy
(±% Full Scale) Typ.
0.25 0.25 0.25 0.25 0.25 0.25
Accuracy
(±% Full Scale) Max.
0.5 0.5 0.5 0.5 0.5 0.5
Temperature Measuring Range
°F
(°C)
-13 ... 221
(-25 ... 105)
-13 ... 221
(-25 ... 105)
-13 ... 221
(-25 ... 105)
-13 ... 221
(-25 ... 105)
-13 ... 221
(-25 ... 105)
-13 ... 221
(-25 ... 105)
Accuracy
(±% Full Scale)
1.5 1.5 1.5 1.5 1.5 1.5

**0 ... 210 PSI (0 ... 15 bar) in conjunction with hydraulic testers of the PPC-04 /2 series
*** Pressure peaks up to 14.500 PSI (1.000 bar)
Note: A PPC-04/12-CAB3 (10 ft. / 3 m) cable is needed to connect the PPC-04/12-PT /2 pressure sensors to the current PPC-04 /2 or PPC-06/08/12 hydraulic testers. A PPC-04/12-CAB5-EXT (16 ft. / 5 m) extension cable is also available as an option.