Axial_Pump_Small.jpg

Series PF120

1.8 G.P.M. - Viton Seals Standard (E.P.R. Seals Available)

0-10,000 P.S.I. Continuous

Motor RPM Delivery G.P.M. Horsepower Input
O PSI 2500 PSI 5000 PSI 7500 PSI 10000 PSI 0 PSI 2500 PSI 5000 PSI 7500 PSI 10000 PSI
1200 1.22 1.19 1.16 1.12 1.09   1.87 3.74 5.61 7.48
1800 1.83 1.78 1.73 1.68 1.64   2.81 5.62 8.42 11.23

 

Axial_Pump_Small.jpg

Series PF300

4.7 G.P.M. - Viton Seals Standard (E.P.R. Seals Available)

0-10,000 P.S.I. Continuous

Motor RPM Delivery G.P.M. Horsepower Input
O PSI 2500 PSI 5000 PSI 7500 PSI 10000 PSI 0 PSI 2500 PSI 5000 PSI 7500 PSI 10000 PSI
1200 3.17 3.09 3.00 2.92 2.84   4.87 9.74 14.60 19.47
1800 4.76 4.63 4.51 4.38 4.26   7.30 14.6 21.91 29.21

 

Axial_Pump_Small.jpg

Series PF500

7.4 G.P.M. - Viton Seals Standard (E.P.R. Seals Available)

0-6,000 P.S.I. Continuous -- 6,000-10,000 P.S.I. Intermittent

Motor RPM Delivery G.P.M. Horsepower Input
100O PSI 2000 PSI 3000 PSI 4000 PSI 6000 PSI 1000 PSI 2000 PSI 3000 PSI 400 PSI 6000 PSI
1200 4.91 4.85 4.80 4.75 4.70 3.04 6.09 9.13 12.17 15.21
1800 7.36 7.28 7.20 7.12 7.05 4.56 9.13 13.69 18.26 22.82

 

Performance - Seven pistons give the GFP/Rodgers axial pump smooth, balanced flow in either direction.  Continuous operation at 10,000 p.s.i. makes them ideal for a wide range of industrial and construction applications.

Efficiency - Close tolerances between the highly ground bronze sleeves and heat treated pistons assure maximum efficiency and durability.

The "Quiet One" - Keeps noise pollution at a minimum.  Smooth, quiet performance over the entire pressure range is accomplished through the 7 piston design.

Hi/Low Design - For maximum efficiency and lowest cost in your hi/low system, GFP/Rodgers axial pumps are designed to enable "piggy-back" mounting for your low pressure pump.  This eliminates the need for double ended motors and pillow block mounting.

Rugged Construction - GFP/Rodgers pumps are precision engineered, machined, and tested to produce hydraulic power economically and efficiently.  Over forty years of proven field experience in 10,000 p.s.i. hydraulics is your assurance of GFP/Rodgers "Task-Force" quality.

Lubrication of bearing and parts is supplied by fluid being pumped.  This makes proper filtration a must, and 100 mesh filtration is recommended.

Pump Shaft Rotation may be clockwise or counter-clockwise except when an auxiliary pump is attached.  Direction of rotation is then determined by the auxiliary pump.

Driving Power to the pump must be applied through axial coupling.  Belt or chain drive is not permitted.

Inlet and Outlet Connections remain as shown in the catalog regardless of direction of shaft rotation.

Inlet Connection may be rotated 180° in relation to the outlet connection from the position shown in the catalog.  The mounting bracket may be changed by removing bracket and relocating in any one of four positions 90° apart.

Available in: Alabama, Arizona, Arkansas, N.W. Florida, S. Idaho, Kansas, Louisiana, Mississippi, W. Missouri, Montana, Nevada, New Mexico, W. North Dakota, Oklahoma, W. South Dakota, Texas, Utah and Wyoming