Sun Hydraulics provides a variety of solenoid and non-solenoid directional control cartridges that include 2-, 3- and 4-way configurations. Sun directional control cartridges can be conveniently applied using many mounting options.

  • Pilot operated and direct acting 2-way and 3-way cartridges that use the same cavity
  • Six-port pilot operated cartridges
  • 2-, 3- and 4-way solenoid cartridges with an industrial grade solenoid
  • High-pressure 2-way solenoid operated poppet valves with flow capacities up to 120 gpm (480 L/min.)
DCC-2P2W&3Ww ID

2-position, 2-way and 3-way, with Internal Drain

  • Maximum operating pressure = 5000 psi
  • Maximum valve leakage = 1 in³/min. at 1000 psi
  • Control pilot flow at opening = DPBA, DPBB, DPBC, DPBD = 7 - 10 in³/min., DPCA, DPCB, DPCC, DPCD = 10 - 15 in³/min.
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • Pressure at port 3 is directly additive to the setting of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
  • For DP*C and DP*D port 3 can be blocked to prevent the cartridge from shifting.
DCC-2P2W&3Ww ED

2-position, 2-way and 3-way, with External Drain

  • Maximum operating pressure = 5000 psi
  • Maximum valve leakage = 1 in³/min. at 1000 psi
  • Control pilot flow at opening = DPBM, DPBN, DPBO, DPBP = 7 - 10 in³/min., DPCM, DPCN, DPCO, DPCP = 10 - 15 in³/min.
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • Pressure at port 4 is directly additive to the setting of the valve.
  • Port 3 can be used as a work port.
  • Port 4 can be blocked to prevent the cartridge from shifting.
DCC-2P2W&3WDAw ID

2-position, 2-way and 3-way Direct Acting, with Internal Drain

  • Maximum operating pressure = 5000 psi
  • Maximum valve leakage = 2 in³/min. at 1000 psi
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • Pressure at port 3 is directly additive to the setting of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
DCC-2P2W&3WDA

2-position, 2-way and 3-way, Direct Acting

  • Maximum operating pressure = 5000 psi
  • Maximum valve leakage = 2 in³/min. at 1000 psi
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • DRBM, DRBN, DRBO, DRBP: Port 3 can be used as a work port
  • DRBM, DRBN, DRBO, DRBP: Pressure at port 4 is directly additive to the setting of the valve.
DCC-3P2W&3Ww IPCC

3-port, 2-way and 3-way with Integral Pilot Control Cavity

  • Maximum operating pressure = 5000 psi
  • Control pilot flow at opening = DVBA-8, DVBB-8, DVBC-8, DVBD-8 = 7 - 10 in³/min., DVCA-8, DVCB-8, DVCC-8, DVCD-8 = 10 - 15 in³/min.
  • Maximum leakage per path = 2 in³/min. at 1000 psi
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • There must be a pressure source at port 1, relative to port 3, to shift the valve.
  • Pressure at port 3 may oppose the opening of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
  • The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
DCC-4P2W&3Ww IPCC

4-port, 2-way and 3-way with Integral Pilot Control Cavity

  • Maximum operating pressure = 5000 psi
  • Control pilot flow at opening = DVBM-8, DVBN-8, DVBO-8, DVBP-8 = 7 - 10 in³/min., DVCM-8, DVCN-8, DVCO-8, DVCP-8 = 10 - 15 in³/min.
  • Maximum leakage per path = 2 in³/min. at 1000 psi
  • Maximum pressure at port 3 should be limited to 3000 psi.
  • There must be a pressure source at port 1, relative to port 4, to shift the valve.
  • The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
DCC-2P2WPC1to 2w IPCC

2-position, 2-way Poppet, Control 1 to 2 with Integral Pilot Control Cavity

  • Maximum operating pressure = 5000 psi
  • The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Main stage leakage less than 5 drops/min.
DCC-2P2WPC2to 1w IPCC

2-position, 2-way Poppet, Control 2 to 1 with Integral Pilot Control Cavity

  • Maximum operating pressure = 5000 psi
  • The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Main stage leakage less than 5 drops/min.
DCC-3P4WSC

3-position, 4-way Spring Centered

  • Maximum operating pressure = 5000 psi
  • Maximum leakage per path = 2 in³/min. at 1000 psi
  • Pilot volume for complete shift = DCCC: 0.02 in³/min., DCDC: 0.06 in³/min., DCEC: 0.17 in³/min., DCFC: 0.42 in³/min.
  • Minimum pilot pressure required to shift valve = DCCC: 175 psi, DCDC: 150 psi, DCEC, DCFC: 125 psi
  • All ports will accept 5000 psi, including the x and y pilot ports (port 5 and port 6).
DCC-2P4WD

2-position, 4-way Detented

  • Maximum operating pressure = 5000 psi
  • Maximum leakage per path = 2 in³/min. at 1000 psi
  • Pilot volume for complete shift = DCCD: 0.05 in³/min., DCDD: 0.12 in³/min., DCED: 0.34 in³/min., DCFD: 0.84 in³/min.
  • Minimum pilot pressure required to shift valve = 40 psi
  • All ports will accept 5000 psi, including the x and y pilot ports (port 5 and port 6).