Sun Hydraulics flow divider and flow divider/combiner cartridges are sliding spool devices that are used to split or combine flow in a variety of applications. Sun flow divider and flow divider/combiner cartridges can be conveniently applied using many mounting options.

  • Offer accurate divisional and combining accuracy in a small size
  • Offer high flow capacity relative to size
  • Are available in a synchronizing version for bi-directional static error correction
  • Operate at pressures up to 5000 psi (350 bar)
FDCCV-D.jpg

Divider

  • Maximum operating pressure = 5000 psi
  • This valve is a divider only; any attempt to flow backwards through the valve is not advised.
  • Divisional accuracy at maximum rated input flow = FSBD: ±2.5%, FSCD, FSDD, FSED, FSFD: ±3.5%
  • Divisional accuracy at minimum rated input flow = FSBD: ±4.5%, FSCD, FSDD, FSED, FSFD: ±6.5%
  • Pressure drop at maximum input flow = 250 psi
  • Pressure drop at minimum input flow = 10 psi
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing control until the flow reaches the minimum rating.
FDCCV-DCCC.jpg

Divider/Combiner, Closed Center

  • Maximum operating pressure = 5000 psi
  • Divisional accuracy at rated maximum input flow = 50% ±2.5%
  • Divisional accuracy at rated minimum input flow = 50% ±4.5%
  • Pressure drop at maximum input flow = 350 psi
  • Pressure drop at minimum input flow = 25 psi
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
  • Divisional and combining accuracy are equal.
FDCCV-SDC.jpg

Synchronizing Divider/Combiner

  • Maximum operating pressure = 5000 psi
  • Divisional accuracy at rated maximum input flow = 50% ±2.5%
  • Divisional accuracy at rated minimum input flow = 50% ±4.5%
  • Pressure drop at maximum input flow = 350 psi
  • Pressure drop at minimum input flow = 25 psi
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
  • The synchronization feature provides bi-directional static error correction.
  • Divisional and combining accuracy are equal.
FDCCV-HCDCCC.jpg

High Capacity Divider/Combiner, Closed Center

  • Maximum operating pressure = 5000 psi
  • Divisional accuracy at rated maximum input flow = 50% ±4%
  • Divisional accuracy at rated minimum input flow = 50% ±6.5%
  • Pressure drop at maximum input flow = 350 psi
  • Pressure drop at minimum input flow = 25 psi
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
  • Divisional and combining accuracy are equal.