Sun Hydraulics
SUN Flow Divider/Combiner Cartridge Valves
Womack Machine Supply Company proudly partners with Sun Hydraulics to deliver the finest Cartridge Flow Control Valves available. Our collaboration ensures that customers in multiple locations across the United States have access to these exceptional products, click here to see available locations. Our commitment to excellence, combined with the reliability and performance of Sun Hydraulics, guarantees that you receive top-quality Cartridge Flow Control Valves components for your specific needs.
Sun Hydraulics flow divider and flow divider/combiner cartridges are sliding spool devices that are used to split or combine flow in a variety of applications. Sun flow divider and flow divider/combiner cartridges can be conveniently applied using many mounting options.
- Offer accurate divisional and combining accuracy in a small size
- Offer high flow capacity relative to size
- Are available in a synchronizing version for bi-directional static error correction
- Operate at pressures up to 5000 psi (350 bar)
Divider
- Maximum operating pressure = 5000 psi
- This valve is a divider only; any attempt to flow backwards through the valve is not advised.
- Divisional accuracy at maximum rated input flow = FSBD: ±2.5%, FSCD, FSDD, FSED, FSFD: ±3.5%
- Divisional accuracy at minimum rated input flow = FSBD: ±4.5%, FSCD, FSDD, FSED, FSFD: ±6.5%
- Pressure drop at maximum input flow = 250 psi
- Pressure drop at minimum input flow = 10 psi
- Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing control until the flow reaches the minimum rating.
Divider/Combiner, Closed Center
- Maximum operating pressure = 5000 psi
- Divisional accuracy at rated maximum input flow = 50% ±2.5%
- Divisional accuracy at rated minimum input flow = 50% ±4.5%
- Pressure drop at maximum input flow = 350 psi
- Pressure drop at minimum input flow = 25 psi
- Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
- Divisional and combining accuracy are equal.
Synchronizing Divider/Combiner
- Maximum operating pressure = 5000 psi
- Divisional accuracy at rated maximum input flow = 50% ±2.5%
- Divisional accuracy at rated minimum input flow = 50% ±4.5%
- Pressure drop at maximum input flow = 350 psi
- Pressure drop at minimum input flow = 25 psi
- Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
- The synchronization feature provides bi-directional static error correction.
- Divisional and combining accuracy are equal.
High Capacity Divider/Combiner, Closed Center
- Maximum operating pressure = 5000 psi
- Divisional accuracy at rated maximum input flow = 50% ±4%
- Divisional accuracy at rated minimum input flow = 50% ±6.5%
- Pressure drop at maximum input flow = 350 psi
- Pressure drop at minimum input flow = 25 psi
- Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
- Divisional and combining accuracy are equal.
AVAILABLE IN THESE LOCATIONS
- Arkansas
- Louisiana
- Oklahoma
- Texas
Contact Us For Pricing And Availability
If you’re interested in any of our products, or you have any questions about pricing and availability, let our team know today. We’re here to help!