DFZ Series
Modular Stacking Filters
4500 PSI • Up to 10 GPM
|
Features
*includes fifth port for optional tank connection. |
Technical Details
Mounting Method | 4 Mounting Holes (Manifold Mount) | |||
Port Connection 30 60/110 |
ANSI DO3/A6 DIN 24340 / Cetop R35 ANSI DO5/A10 DIN 24340 / Cetop R35 |
|||
|
|
|||
Construction Materials Head, Bowl |
Steel |
|||
Flow Capacity 30 60/110 |
8 gpm (30 lpm) 16 gpm (60 lpm) |
|||
Housing Pressure Rating Maximum Operating Pressure Proof Pressure Fatigue Pressure - 30 Fatigue Pressure - 60/110 Burst Pressure |
4500 psi (315 bar) 6750 psi (472 bar) 4500 psi (315 bar) @ 250,000 cycles 4500 psi (315 bar) @ 1 million cycles >18,270 psi (1260 bar) |
|||
Element Collapse Pressure Rating BH/HC, V |
3000 psid (207 bar) |
|||
Fluid Temperature Range | -22° to 250°F (-30° to 121°C) | |||
Fluid Compatability Compatible with all petroleum oils and synthetic fluids rated for use with Fluoroelastomer or Ethylene Propylene seals. Contact HYDAC for information on special housing and element constructions available for use with water glycols, oil/water emulsions, and HWBF. |
||||
Indicator Trip Pressure ΔP = 116 psid (8 bar) - 10% (Standard) |
Available in: Alabama, Arizona, Arkansas, N.W. Florida, S. Idaho, Kansas, Louisiana, Mississippi, W. Missouri, Montana, Nevada, New Mexico, W. North Dakota, Oklahoma, W. South Dakota, Texas, Utah and Wyoming