OPERATION SCHEMATIC
RVP100 SERIES RESERVOIR, AIR OPERATED / DUAL REGULATORS ONLY
RESERVOIR CONNECTIONS (See drawing to the right) |
|
|
I | 1/4 NPTF incoming shop air | |
II | Regulated air to valve - 1/4 NPTF | |
III | Regulated oil to valve - 1/8 NPTF | |
RESERVOIR FEATURES | ||
1 | Select capacity. 1 quart to 2 gallon (0.946 liter - 7.6 liter) polymer. | |
2 | Filler cap. | |
3 | Regulator - fluid pressure 30 PSIG (206.9 kPa) maximum. | |
4 | Pressure gage - fluid. | |
5 | Relief valve - set 30 PSI (206.9 kPa). | |
6 | Regulator - air to spray valve. | |
7 | Pressure gage - 0-30 PSI (0-206.9 kPa) to spray valve. | |
8 | Filter - 40 micron. |
SUGGESTIONS FOR SOLENOID OPERATION
CONTINUOUS SPRAY:
- Wire both solenoids to auxiliary contacts on the "machine" being lubricated.
- If over-run of liquid can be tolerated when the "machine" is shut down you can simplify the installation by omitting solenoids C and E and replacing the ball valve A with one solenoid valve P/N ESV512 wired to the auxiliary contacts.
TRIGGERED SPRAY with a rate less than 1O cycles per minute:
- Wire both solenoids to an electromechanical switch or a non-contact switch which is activated by "machine" movement. Solenoid E for air should be installed as close as possible to the spray valve B.
PULSED OR TRIGGERED SPRAY with a rate more than 1O cycles per minute:
- Wire solenoid C for liquid to a repeat cycle timer or "machine" activated trigger switch. Wire solenoid E for air to the "machine" auxiliary contacts so the air flows continuously to minimize droplet formation.
Do not use a filled fluid such as molydisulfide dispersion, teflon dispersion or any other particle dispersion. They will clog the fine openings of the unit, requiring a total dismantling of the system.
ITEM NOT INCLUDED WITH RESERVOIR | |
A | 1/4 x 1/4 ball valve - shop air shut off. |
B | Spray Valve (P/N SV101, SV102 or SV103). |
C | Solenoid valve (P/N ESV501) - shut off oil to spray valve. |
D | 0.25 (6.35 mm) O.D. semi-rigid or metal as needed, and required fittings. |
E | Solenoid valve (P/N ESV501) - shut off air supply valve. |
Available in: Alabama, Arizona, Arkansas, N.W. Florida, S. Idaho, Kansas, Louisiana, Mississippi, W. Missouri, Montana, Nevada, New Mexico, W. North Dakota, Oklahoma, W. South Dakota, Texas, Utah and Wyoming